True metrix error codes e 0 - The True Metrix Air blood glucose monitoring system with Bluetooth Smart wirelessly transmits glucose results to mobile device. Triple Sense Technology automatically detects, analyses and corrects variables in each blood sample to ensure proven accuracy and confidence in results. Event tagging - the True Metrix Air System features advanced ...

 
The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider.. 873 chorizo de bellota precio por pieza

Perform Control Tests before performing a blood glucose test for the first time. Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, Monday - Friday, 8AM-8PM EST, for assistance in obtaining diferent levels of control solution.Apr 19, 2021 · An “E2” code indicates INSUFFICIENT BLOOD DROP or that the test strip has not filled enough for an accurate test. Another possible cause is difficulty seeing where to apply blood to strip. To correct, remove the test strip and retest using a new test strip. Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, available 24 hours a day, 7 days a week, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY.True Metrix Pro - Home - Trividia Health TRUE METRIX® Blood Glucose Monitoring System Troubleshooting Steps Meter Does not Turn on with Strip Meter is dead or does not power on with a strip insertion or by pressing the power button. Battery symbol appears and beeps before meter turns off. Dead meter or meter does not turn on can be caused by: • A dead battery.TRUE METRIX® AIR Self Monitoring Blood Glucose System TRUE METRIX AIR is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to provide quality healthcare products and dedicated customer service. For questions about TRUE METRIX products, visit our web site at: www.trividiahealth.com.This website makes use of licensed stock photography. All photography is for illustrative purposes only and all persons depicted are models. This website contains information on products which are targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country. Please be aware that we do n Wash hands thoroughly in warm soapy water, dry thoroughly, put the lancet in the injector, inject, get blood out of finger, and it goes in where it's supposed to. But it never reads. It …This code applies to a machine with LAE electronic controls only. Associated models – T-23, T-49, TFP, TMW, TPP, TSD, TSSU, TWT, GDM-26-HC, GDM-49-HC and GDM-69-HC-LD; For more help, check out our other tips for commercial fridge troubleshooting or our selection of True manuals and diagrams.this is about the pharmacy give my mom since vor testing, after she is with medicare.she has been having a frightful time with it. More than 50% of the time...Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025 for assistance in obtaining control solution. The TRUE METRIX Self Monitoring Blood Glucose System is for one person use ONLY. DO NOT share your meter or lancing device with anyone, including family members.Apr 4, 2023 · Potential error codes that may occur while testing blood sugar. Specific Error Codes E 0 1:10 E 1 1:32 E 2 1:53 E 3 2:18 E 4 2:40 E 5 2:49 E 6 3:11 E 9 3:32 Other error... The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider.Apr 25, 2020 · En este caso queremos que conozcas los errores más comunes que presentan los glucómetros, un dispositivo que ha sido pionero e indispensable en el tratamiento de la diabetes, pero que en algún momento pueden fallar y por eso es importante saber qué significa cada falla. Errores comunes en los glucómetros Call 1-800-803-6025, Monday - Friday, 8AM-8PM EST, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY. DO NOT share your meter or lancing device with anyone, including family members. Do not use on multiple patients! Confusion matrix. display_labelsndarray of shape (n_classes,), default=None. Display labels for plot. If None, display labels are set from 0 to n_classes - 1. Attributes: im_matplotlib AxesImage. Image representing the confusion matrix. text_ndarray of shape (n_classes, n_classes), dtype=matplotlib Text, or None.E-5 error message can be associated with blood glucose results > 600mg/dL. Symptoms of hyperglycemia may include but are not limited to, shaky or dizzy, blurred vision, extreme …Meter Displays E-0 When Testing with Blood: Invalid Hematocrit. The system is designed to give accurate glucose results from a blood sample that is within the Hematocrit (HCT) range of 20% -70%. If your HCT result is < 20% or > 70% the meter will display an E-0 error message. E-0 message is a safety feature alert, that the sample type may be ... Test Time: Results can be ready in 4 seconds. Power Supply: One non-rechargeable 3V lithium battery. Battery Life: Approximately 1,000 tests/1 year. Automatic Shut-Off: After sitting idle for two minutes. Weight: 1.66 ounces. Size: 3.44” x 2.16” x 0.69”. Memory Size: 1,000 test results (both blood and control tests) Operating Range (for ...• Code is assigned during manufacturing process Environmental and ... 8.1 mg/dL 64 mg/dL -----Triglyceride 150 mg/dL 1000 mg/dL -----Uric acid 3 mg/dL 9.0 mg/dL 5 mg/dL Xylose 5.0 mg/dL 58 mg/dL 7 mg/dL TRUE METRIX™ PRO ... The following is a brief guide for Troubleshooting the ™ most common errors when using TRUE METRIX ...TRUE METRIX Self Monitoring Blood Glucose Meter - YouTube There are many different ones available in the market although True Metric has been one of the greatest popularity ones recent. The software helps you with an advanced package systematisches that is useful to build lifestyle decisions basic on what lift your lactose …Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone.E-5 message is a safety feature to alert customers that there may potentially be issues with the test strip or the blood glucose result being detected by the meter is higher than 600mg/dL.True Metrix Air. For daily self-monitoring of blood glucose, a meter lets you check your levels with the prick of a finger. The meter tracks 7-, 14-, 30-, 60-, and 90-day blood glucose averages. Offers four alarms and a reminder to test for ketones. The user can set event tags for medication, pre- and post-meal, exercise, and sick days. Oct 2, 2009 · The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider. E-3. Your blood glucose may be too low to be read by the system, or there may be a problem with the test strip. Monitor your blood glucose again with a new test strip. If “E-3” shows again, contact your health coach immediately.Meter Displays E-0 When Testing with Blood: Invalid Hematocrit. The system is designed to give accurate glucose results from a blood sample that is within the Hematocrit (HCT) range of 20% -70%. If your HCT result is < 20% or > 70% the meter will display an E-0 error message. E-0 message is a safety feature alert, that the sample type may be ... Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, available 24 hours a day, 7 days a week, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY.Advanced technologies – the meter, a complex algorithm, chemistry and electrodes on the test strip – work together as part of the TRUE METRIX® system to produce accurate results. Features TRIPLE SENSE TECHNOLOGY® automatically detects, analyzes and corrects variables 1 in each blood sample to ensure proven accuracy and confidence in results. Performance problems include falsely high or low results or incorrect calibration. These errors could be related to the meter or the test strips. The meter company will be able to help discover which. Some blood glucose meters require a calibration code to be entered which can lead to mistakes and errors.Blood Glucose Control Solution McKesson Quintet AC® 2 X 4 mL Level 1 & 2. #960301. 2,000. McKesson Brand #06-R5051-2. Blood Glucose Control Solution McKesson TRUE METRIX® 3 mL Level 2. #711309. 1,992. Arkray USA #500006. Blood Glucose Control Solution Assure® Dose 2 X 2.5 mL Level 1 & 2.Trividia True Metrix Blood Glucose Test Strips - 50 Strips. (2) £19.55. 50 UNI|£0.39 per 1UNI.This code applies to a machine with LAE electronic controls only. Associated models – T-23, T-49, TFP, TMW, TPP, TSD, TSSU, TWT, GDM-26-HC, GDM-49-HC and GDM-69-HC-LD; For more help, check out our other tips for commercial fridge troubleshooting or our selection of True manuals and diagrams. TRUE METRIX® AIR Self Monitoring Blood Glucose System TRUE METRIX AIR is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to provide quality healthcare products and dedicated customer service. For questions about TRUE METRIX products, visit our web site at: www.trividiahealth.com.The P0299 code results from low air pressure coming to the turbine of the turbocharger. The problem can be vacuum leaks, EGR issues, a damaged turbo, or a problem with the boost pressure sensor. The result is that the engine will not accelerate as it should. Depending on the vehicle, the ECU may even trigger a limp mode.True Metrix Pro - Home - Trividia Health this is about the pharmacy give my mom since vor testing, after she is with medicare.she has been having a frightful time with it. More than 50% of the time...15197:2015(E). Brussels: European Committee for Standardization; 2015. 2 SYSTEM SPECIFICATIONS. IMPORTANT HEALTH and SAFETY INFORMATION • Use of the TRUE METRIX GO System in a manner not specified in this System Instructions for Use is not recommended and may affect the ability to determine true blood glucose levels.11,338 satisfied customers. True treadmill Mod.: 5500P Ser. #00-18959H indicating code. True treadmill Mod.: 5500P Ser. #00-18959H indicating code on monitor Stall e1 … read more.I have True Metrix meter, only gotten E-0 code once. Not enough blood. I always lift my arm, and hold for minute then use lancet, don't squeeze finger.Get …200 OK. The request succeeded. The result meaning of "success" depends on the HTTP method: GET: The resource has been fetched and transmitted in the message body.; HEAD: The representation headers are included in the response without any message body.; PUT or POST: The resource describing the result of the action is …Ok I did some tests myself with the Metrix and some other meters I had lying around. I have a TRUEresult meter, a TRUEtrack, and this True Metrix. All tests were done with washed hands and within 5 minutes. TRUEresult - 90, 90, 96 TRUEtrack - 93, 104 TRUE Metrix - 99, 104, 95 So I guess it's pretty accurate. The meter itself seems fine.My mother-in-law had a walgreens meter and it did that giving an e code even though it appeared to boot up when you put a strip in it. Changing the batteries fixed it. Hers took two CR2032 button batteries. So if you have had it awhile maybe check those batteries. HP Printer Driver Support for Linux OS. Linux operating systems are developed and supported by the open source community. To find driver support for the Linux operating system, HP recommends the HP Linux Imaging and Printing website HP Linux Imaging and Printing . Note: The HP Linux Imaging and Printing website is not hosted by HP …McKesson TRUE METRIX® PRO Professional Monitoring Blood Glucose Meter For use with #06-R3051P-01 and #06-R3051P-05 McKesson TRUE METRIX® PRO Strips, and #06-R5051-1, #06-R5051-2 and #06-R5051-3 McKesson TRUE METRIX® Controls. No coding. As fast as 4 seconds. Tiny 0.5 microliter sample size. Alternate site testing. Store 500 …If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.The TRUE METRIX Self Monitoring Glucose Meter by Trividia Health is a reliable monitor for quick and accurate blood glucose testing. The TRUE METRIX meter tests blood sugar from the fingertip or forearm and is able to store 500 results with the date and time. TRUE METRIX Meter Features: Alternate site testing Data storage Testing …Ok I did some tests myself with the Metrix and some other meters I had lying around. I have a TRUEresult meter, a TRUEtrack, and this True Metrix. All tests were done with washed hands and within 5 minutes. TRUEresult - 90, 90, 96 TRUEtrack - 93, 104 TRUE Metrix - 99, 104, 95 So I guess it's pretty accurate. The meter itself seems fine.Shop True Metrix Go Self-Monitoring Blood Glucose Meter and read reviews at Walgreens. Pickup & Same Day Delivery available on most store items. Skip to main content App exclusive! Earn $10 rewards on $50&plus; Up to 60% off clearance; Clip your mystery deal! Menu. Sign in Create an account. Find a ...Solution. • This means not enough blood. or sample not detected. • Re-test to make sure there. is enough blood and that. you're filling the test strip. properly. • Bring the tip of the strip ...Call 1-800-803-6025, Monday - Friday, 8AM-8PM EST, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY. DO NOT share your meter or lancing device with anyone, including family members. Do not use on multiple patients! Nov 30, 2017 · type 2 since 2016. Dec 1, 2017. #5. I have been using a True Metrix meter for several months now myself and have experienced no problems with it other than of my own making. The meter is operating just fine. It shuts itself off after 15 seconds or so after a test and stays off until I insert a new strip. If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.Professional Monitoring Blood Glucose System (using TRUE METRIX™ PRO Test Strips with GDH-FAD Enzyme) Comprehensive Resource Guide for Healthcare Professionals (Policies, Processes, and Procedures) Information in this guide is specific For assistance please call: for healthcare professionals using the Customer Care 1-800-803-6025 TRUE METRIX ... E-5 error message can be associated with blood glucose results > 600mg/dL. Symptoms of hyperglycemia may include but are not limited to, shaky or dizzy, blurred vision, extreme …OUR PRODUCTS. Keeping your blood glucose in a healthy range can be challenging, but we can help. You can be confident in the accurate results and reliable performance of the TRUE family of blood glucose monitoring systems and accessories. At an affordable price, our monitoring solutions bring high quality within reach for more people with diabetes.Oct 15, 2016 · Oct 21, 2016. #8. I have True Metrix meter, only gotten E-0 code once. Not enough blood. I always lift my arm, and hold for minute then use lancet, don't squeeze finger.Get accurate readings which I download into docking station automatic. I really like new meter, also True Test meters work in docking station, I wasn't told this years ago, but ... Professional Monitoring Blood Glucose System (using TRUE METRIX™ PRO Test Strips with GDH-FAD Enzyme) Comprehensive Resource Guide for Healthcare Professionals (Policies, Processes, and Procedures) Information in this guide is specific For assistance please call: for healthcare professionals using the Customer Care 1-800-803-6025 TRUE METRIX ... Apr 28, 2022 · Codes from the Manual: E-1: Temperature is too hot or too cold for the system to work properly. Move your monitor and test strips to a location where the temperature is appropriate and monitor again with a new test strip. True Metrix Pro - Home - Trividia Health TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) Intended Use Statement 2 Intended Use Statement The TRUE METRIX™ PRO Blood Glucose Monitoring System is intended for the quantitative determination of glucose in human whole blood taken from the fingertip or forearm (capillary) or from the vein (venous). The system is ... With the TRUE MANAGER™ AIR Mobile App, TRUE METRIX® AIR Blood Glucose Meter with Bluetooth Smart technology, and certain mobile devices, you can track data to get valuable insights that link daily activity with your glucose results from the meter’s memory. Easy-to-read charts, graphs and customizable notes make understanding data …If your HCT result is < 20% or > 70% the meter will display an E-0 error message. E-0 message is a safety feature alert, that the sample type may be invalid due to improper testing technique. The meter is designed to trigger this alert instead of giving inaccurate …Call 1-800-803-6025, Monday - Friday, 8AM-8PM EST, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY. DO NOT share your meter or lancing device with anyone, including family members. Do not use on multiple patients!How to use Level 1, Level 2 and Level 3 control solution with the True Metrix Blood sugar meters.Buy control solution at Diabetic Warehouse https://bit.ly/39...TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) System Specifications 4 System Specifications Meter Specifications Result Range: …Learn how to use the TRUE METRIX® blood glucose meter and test strips to monitor your blood sugar levels at home. This booklet provides step-by-step instructions, safety tips, …Includes Glucose Meter, Installed 3-Volt Battery, Instructions for Use, and Compact Carrying Case. Auto coding for quick and accurate testing. 1,000 test battery life. Easy-to-read LCD screen with backlight. Minimal sample size of 1.0 uL. Large memory; capable of …3. The test strip may not be fully inserted into the strip port. What to do: Remove and reinsert the test strip properly. If issue persists contact Customer Support at 1-800-348-8100.Blood glucose test result is above 600 mg/dL; blood ketone test result is above 8.0 mmol/L. Wash and dry your hands or test site and repeat the test using a new test strip. If your result still flashes HI, contact your health coach immediately.An E6 or E7 error code is an incline error code. The E7 code means the potentiometer value the console is reading from the lift motor is out of range.Like its partner model, the True Metrix Go meter uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. It also offers a 500-test memory, 7-, 14-, and 30-day averages, and data downloading capabilities. User reviews. This meter received high reviews, averaging 4.8 out of 5 stars from a dozen reviews on the …Deductible. Post-Deductible. Donut Hole. Post-Donut Hole. Copay Range. $60. After your deductible has been satisfied, you will enter the Post-Deductible (also called Initial Coverage) stage, where you pay your copay and your plan covers the rest of the drug cost. Want an exact price for your co-pay? Select Your Plan.Calculating a confusion matrix can give you an idea of where the classification model is right and what types of errors it is ... macro avg 0.70 0.71 0.70 10 weighted avg 0.72 0.70 0.70 10. R Code for Confusion Matrix: Let’s use R ... if you want to cover all true negatives, i.e. meaning we do not want any false ...An "E2" code indicates INSUFFICIENT BLOOD DROP or that the test strip has not filled enough for an accurate test. Another possible cause is difficulty seeing where to apply blood to strip. To correct, remove the test strip and retest using a new test strip. Wait until you see the flashing blood drop on the display before testing and make sure ...Codes from the Manual:E-1: Temperature is too hot or too cold for the system to work properly. Move your monitor and test strips to a location where the temperature is appropriate and monitor again with a new test strip. You may have to wait for your monitor to adjust to the new temperature. Refer to your test strip instructions for use …Was released from the vet last night and this morning all I am getting on the blood meter reading is E-5. I tested on me and got a normal numerical reading. I fed her and gave 2 units of Lantus at 8am and retested there blood at 11 and still got E-5. using the Trueresult metering system. My vet opens at 3pm which seems a long time away.The True Metrix meter also has features such as a ketone reminder, control detection, and audible fill detection to keep users on track. Strip Release Button Handling a strip after testing can have an impact on its accuracy. The True Metrix blood glucose meter has a handy strip release button.What does e2 mean on true metrix, My mother-in-law had a walgreens meter and it did that giving an e code even though it appeared to boot up when you put a strip in it.Changing the batteries fixed it. Hers took two CR2032 button batteries. What this means: The environmental temperature is lower than 50 degrees F (10 degrees C).Apr 28, 2022 · Codes from the Manual: E-1: Temperature is too hot or too cold for the system to work properly. Move your monitor and test strips to a location where the temperature is appropriate and monitor again with a new test strip. The TRUE METRIX AIR Blood Glucose Meter can be used on multiple patients. Healthcare Professionals always need to wear gloves and follow Cleaning/Disinfecting section and/or adhere to the infection control policies and procedures approved by their facility. The test strips and lancets are for single-use.

Add a tiny drop of blood, and the meter will show your blood sugar (blood glucose) level on a display screen. How often you check depends on a number of factors, including your diabetes type and whether you're taking insulin, so talk to your health care provider for guidance. Other meters may be available that are not listed here.. Api schema

true metrix error codes e 0

We would like to show you a description here but the site won’t allow us. Error Code. Support Code. Cause. Action. E02. 1000. 3442. 3443. 3444. 3445. Printer is out of paper.. Printing one side is complete if you are performing manual ...Trividia True Metrix Blood Glucose Test Strips - 50 Strips. (2) £19.55. 50 UNI|£0.39 per 1UNI.True Treadmill Errors and Service Messages The True 600, 700, 725, and 750 series treadmills are equipped with built-in diagnostics and...Test with confidence with the TRUE METRIX® AIR Self Monitoring Blood Glucose System. TRUE METRIX® AIR features integrated wireless capability, TRIPLE SENSE TECHNOLOGY® and enhanced event tags to empower users to make the connection between personal lifestyle and results. Providing this information helps users make informed choices to ... Nov 30, 2017 · type 2 since 2016. Dec 1, 2017. #5. I have been using a True Metrix meter for several months now myself and have experienced no problems with it other than of my own making. The meter is operating just fine. It shuts itself off after 15 seconds or so after a test and stays off until I insert a new strip. A confusion matrix is a matrix that summarizes the performance of a machine learning model on a set of test data. It is a means of displaying the number of accurate and inaccurate instances based on the model’s predictions. It is often used to measure the performance of classification models, which aim to predict a categorical label for each ...True Metrix Air. For daily self-monitoring of blood glucose, a meter lets you check your levels with the prick of a finger. The meter tracks 7-, 14-, 30-, 60-, and 90-day blood glucose averages. Offers four alarms and a reminder to test for ketones. The user can set event tags for medication, pre- and post-meal, exercise, and sick days.• Code is assigned during manufacturing process Environmental and ... 8.1 mg/dL 64 mg/dL -----Triglyceride 150 mg/dL 1000 mg/dL -----Uric acid 3 mg/dL 9.0 mg/dL 5 mg/dL Xylose 5.0 mg/dL 58 mg/dL 7 mg/dL TRUE METRIX™ PRO ... The following is a brief guide for Troubleshooting the ™ most common errors when using TRUE METRIX ...Test with confidence with the TRUE METRIX® AIR Self Monitoring Blood Glucose System. TRUE METRIX® AIR features integrated wireless capability, TRIPLE SENSE TECHNOLOGY® and enhanced event tags to empower users to make the connection between personal lifestyle and results. Providing this information helps users make informed choices to ... In rare cases, an E-3 message may indicate that your blood glucose is extremely high and above the system’s measuring range. In addition, the message could appear if the cap on the test strip container was not closed tightly.Shop True Metrix Go Self-Monitoring Blood Glucose Meter and read reviews at Walgreens. Pickup & Same Day Delivery available on most store items.The Walgreens True Metrix also uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. This meter offers a 500-test memory, alternate site testing, 7-, 14-, and 30-day averages, event tagging, and the …Oct 15, 2016 · Oct 21, 2016. #8. I have True Metrix meter, only gotten E-0 code once. Not enough blood. I always lift my arm, and hold for minute then use lancet, don't squeeze finger.Get accurate readings which I download into docking station automatic. I really like new meter, also True Test meters work in docking station, I wasn't told this years ago, but ... True Treadmill Errors and Service Messages The True 600, 700, 725, and 750 series treadmills are equipped with built-in diagnostics and...If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t. True Metrix Pro - Trividia HealthHow to Test Control Solution Use ONLY TRUE METRIX Control Solution with the TRUE METRIX AIR Meter and TRUE METRIX Test Strips. 1. Check dates on control solution label and test strip vial label. Do not use control solution or test strips if either Use By Dates have passed. Page 20 5. Insert test strip into Test Port. Meter turns on.TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) System Specifications 4 System Specifications Meter Specifications Result Range: 20-600 mg/dL Sample Size: Minimum 0.5 microliter (0.5 µL) Sample Type: Fresh capillary whole blood, venous whole blood collected in sodium heparin blood collection tubes only, ….